You are in the Privatkunden-Shop (Switch to business to business shop)
Bitte warten...

Air Consumption Meter / Compressed Air Counter

From  1.598,25
Preis inkl. MwSt.
Free Shipment

Do you have any questions?
We would like to assist you!
 
Product Description
  • Switch, Impulse or Analog Outlets for external processings
  • Manintenance Intervals can be Usage-Bound assigned
  • Fall of Pressure Free Measurement because of the special construction of Measuring Sensors
  • Reaction Time Milliseconds
  • Exact Measurement of the Pressure and Temperature Max. 60°C
Application
  • Application
  • Air Consumption Meter / Compressed Air Counter
  • Least Leakage are beeing recognized
  • Air Consumption Amounts can be assigned to Production Units
  • Display or the Total Air Consumption or the Actual Consumption On-Site

Versions: (5)

Male
DN
Length
Height
Measuring Range Nmµ/h
Measuring Range Nl/min

Artikel-Nr. Male DN Length Height Measuring Range Nmµ/h Measuring Range Nl/min Preis inkl. MwSt.
LVM100000000 R 1" 25 475 89 0,75 - 225 12,5 - 3750
 1.598,25
Preis inkl. MwSt.
LVM112000000 R 1 1/2" 38 475 121 1,3 - 410 22,2 - 6830
 1.979,66
Preis inkl. MwSt.
LVM120000000 R 1/2" 15 300 77 0,25 - 75 4 - 1250
 1.514,13
Preis inkl. MwSt.
LVM200000000 R 2" 50 475 133 2,3 - 700 390 - 11670
 2.085,40
Preis inkl. MwSt.
LVMNETZ00000 Accessory Power Supply
 173,61
Preis inkl. MwSt.

Detailed Description

Air Consumption Meter / Compressed Air Counter
Product Description
  • Switch, Impulse or Analog Outlets for external processings
  • Manintenance Intervals can be Usage-Bound assigned
  • Fall of Pressure Free Measurement because of the special construction of Measuring Sensors
  • Reaction Time Milliseconds
  • Exact Measurement of the Pressure and Temperature Max. 60°C
Application
  • Application
  • Air Consumption Meter / Compressed Air Counter
  • Least Leakage are beeing recognized
  • Air Consumption Amounts can be assigned to Production Units
  • Display or the Total Air Consumption or the Actual Consumption On-Site
Technical Data
  • Operating Voltage 19 to 30 V DC
  • Display Unit/Measurement Unit: Nl/min or Nm³/h
  • Reaction Time. 100 ms
  • Measurement Error: Air Class 141: ñ(3% of Result +0,3% of the Upper Range Value)
  • Ampacity / Charging Rate: 2 x 250 mA / 100 mA
  • Analog Outlet: 4 to 20 mA
  • Max. 500 Ohm
  • Impulse Outlet: 1 Nl or 1 Nm³ per Impulse (Impulse Length 2 or 100 ms adjustable)
  • Switching Output (Opener/Shutter) PNP, Hysteresis or Switching Window

Ratings

I would like to evaluate this item!

No evaluation has been given
Alternative artilce codes: noinc