Fixed point distribution and control unit - with Wita or Grundfos pump - DN20 - connection 1" - up to 6 bar - up to 100°C

From  307,32
Price incl. VAT
plus 29,00 shipping costs

Do you have any questions?
We would like to assist you!
 
Product Description
  • The manifold for central heating systems is used in heating systems in residential, commercial and industrial buildings to distribute the heat transfer medium from a single heat source to several distribution or control units. The fixed point distribution and control unit can be used flexibly both in traditional radiator systems and in modern panel heating systems. It can also be installed in combination with both boilers and heat pumps. The distribution and control unit for central heating systems also ensures that heating or air conditioning systems are supplied with a heat transfer medium.
  • For operation in different user zones with a single heat source, an optimum zone division is made possible by mounting several distributor units on a distributor for central heating systems.
Description
  • Distribution units are ideal components for optimising a central heating system, both in terms of the energy efficiency of the system and the operation and maintenance of the system.
  • The fixed-point distribution and control unit is more complex than simple direct distributors. It ensures the supply of a heat transfer fluid from a primary side to a secondary side. In low-temperature surface heating systems, it maintains the fluid temperature at the set value. The flow temperature can be set manually between 20°C and 70°C using the thermostat controller.
  • The small distance of 90 mm between the flow and return allows for an extremely compact installation.
  • The direct manifold is supplied with an EPP insulated housing, a wall bracket, a ball valve for shutting off on the primary side, a ball valve for shutting off on the secondary side with thermometers and a high-efficiency circulation pump.
  • The positioning of the components within the thermal insulation shell can be changed, allowing the flow and return to be reversed during installation.
Technical Data
  • Kv - 7.5 m³/h (The flow coefficient Kv refers only to the mixing valve)
  • Maximum operating pressure - 6 bar
  • Maximum operating temperature - 100 °C
  • System-side connection - 1"
  • Boiler-side connection - 1"
  • Centre distance - 90 mm
  • Setting the flow temperature - 20°C to 70°C
  • Threaded connections - ISO228 (corresponds to DIN EN ISO 228 and BS EN ISO 228)
  • Non-return valve in the return flow
  • Right - left reversible
  • Width - 180 mm
  • Height - 330 mm
  • Depth incl. thermostat control - 170 mm
Versions: (2)
Narrow down your selection
Pump type
Anzeigen als list Table
Item No.: 509795290CP0
Type
Pump typewith Wita pump
307,32
Price incl. VAT
plus 29,00 shipping costs
Delivery time 3 weeks
Item No.: 509795290CPG
Type
Pump typewith Grundfos pump
330,69
Price incl. VAT
plus 29,00 shipping costs
Delivery time 3 weeks
This article is accessory of...
Ratings


No evaluation has been given
Search terms: Distributor, Distribution unit, Fixed point distribution and control unit, Fixed point dividing unit, Fixed point control unit, Control unit, Distribution unit with thermostatic controller, Manifold with thermostatic controller, Control unit with thermostatic controller, Heating manifold, Central heating system, Central heating, Radiator systems, Radiator, Floor heating systems, Floor heating, Heating system, Air conditioner, Energy efficiency