Item No.:
1091EV125000
Product Description
- The EV125 automatic solvent distiller from Ciemme is designed for the recovery of solvents in industrial processes.
- The EVOLUTION series is designed for businesses that process large quantities of solvents, for example in the printing, painting, coating and pharmaceutical industries.
- According to the manufacturer’s specifications, the solvent distiller has an ATEX classification of equipment category 2G and is intended for use in Zone 1 potentially explosive atmospheres.
- The automatic solvent distillers in Ciemme’s EVOLUTION series are designed for the treatment and recovery of solvents in industrial production processes.
- These distillers enable the separation of solvents and the residues they contain through distillation. Depending on their composition and the specific process requirements, the treated solvents can be reused.
- The EVOLUTION series is designed for integration into industrial production processes and features automatic process control.
- The distillation parameters can be set via a PLC control panel. The distillation cycle then runs automatically.
- At the start of the cycle, the feed pump delivers the solvent to be processed into the evaporation tank. As soon as the specified level is reached, the pump stops automatically and the heating process begins.
- The distilled solvent is then automatically channelled into a designated collection tank.
- A cooling phase takes place at the end of the distillation cycle. As soon as the preset temperature is reached, the remaining residue is automatically drained off.
- Daily output – 500 to 700 l/24h
- Average peak output – 30 to 35 l/h
- Loading capacity – 120 l
- Total tank capacity 170 litres
- Manhole cover gasket – PTFE
- Heating capacity – 9.6 kW
- Diathermic oil capacity – 60 l
- Pneumatic feed pump – 3/4" PTFE diaphragm
- Pneumatic pump for distilled solvents – 3/4" PTFE diaphragm
- Diameter of the residual drain valve – 2 1/2"
- Residue drain tank – 200-litre drum – optional IBC
- Hydraulic power unit motor – 1.5 kW
- Diathermic oil pump motor – 0.37 kW
- Fan for oil cooling – 0.18 kW
- Steam-cooled fan – 0.55 kW
- Cooling fan diameter 400 mm
- Mains supply voltage – 400 V / 3-phase + N / 50 Hz
- Connection cable – 5G3 N+T
- Compressed air connection – 5/6 bar – 10 mm hose
- Compressed air consumption – 300 Nlt/min
- Noise level – 75 dB
- Approximate overall dimensions L x W x H (varies depending on configuration) – 3000 x 1400 x 3500 mm
- PLC control system – Siemens S7 1200 Series
- Control panel – Weintek
- Operating temperature: -50 to 190 °C
- Certification – II 2G Ex h IIB T3 – II 1/2 G Ex h IIB T3 Ga/Gb